FXO-HC33 Series
Mechanical Testing
Parameter
Mechanical Shock
Mechanical Vibration
High Temperature Burn-in
Hermetic Seal
Test Method
Drop from 75cm to hardwood surface – 3 times
10~55Hz, 1.5mm amplitude, 1 Minute Sweep
2 Hours each in 3 Directions (X, Y, Z)
Under Power @ 125°C for 2000 Hours (results below)
He pressure: 4 ±1 kgf / cm 2 2 Hour soak
2,000 Hour Burn-In
Burn-In Testing – under power 2000 Hours, 125°C
Page 22 of 24
? 2012 FOX ELECTRONICS | ISO9001:2008 Certified
DWG-5052